Endoscopy June 2021 PMID 32882721

Impact of sedation on the Performance Indicator of Colonic Intubation.

Karlijn J Nass, Sascha C van Doorn, Manon van der Vlugt, Paul Fockens, Evelien Dekker

Download social card

Mentions

4
Peak: 1 in May 2021
across 3 sources since May 2021

Extended reach

11,571
potential audience

Total likes

1

Video views

38

Mentions per month

May 2021 – Jun 2021

Where it's discussed

  • Facebook2 posts
  • X / Twitter1 posts
  • YouTube1 videos

AI synopsis

What people are saying

People emphasize the importance of sedation management in colonoscopy, with phrases like 'significant impact' and 'must consider' illustrating the perceived influence of the findings, while detailed references to the PICI measure and ADR underline their engagement with the study's clinical implications.

AgreementModerate agreement

Most discussions seem to agree that the study highlights important factors affecting colonoscopy quality, especially regarding sedation practices and their influence on PICI and ADR.

InterestHigh interest

Posts show high interest by referencing specific aspects of the research, such as sedation levels, PICI, and the variation among endoscopists.

EngagementModerate engagement

Comments include detailed reflections on the methodology and implications, indicating a moderate level of engagement.

ImpactModerate impact

The discussions recognize the study's potential influence on clinical practices and quality indicators, though some mention variability limits broad application.

Abstract in brief

  • The study introduces the Performance Indicator of Colonic Intubation (PICI), a new measure of high-quality colonoscopy, defined by successful cecal intubation, minimal patient discomfort, and low sedation use, and assesses its relationship with adenoma detection rate (ADR).
  • The findings show that adequate PICI was achieved in about 46-49% of colonoscopies, and it was associated with higher ADR, indicating better detection of adenomas when PICI criteria were met; however, higher sedation doses often correlated with inadequate PICI.
  • Due to significant variation in sedation practices among different endoscopists and countries, the utility of PICI as a consistent quality indicator may be limited, highlighting the influence of sedation habits on colonoscopy quality measures.]

Top posts

Most liked on X and Bluesky
Endoscopy Journal
@endoscopyjrnl · X

Karlijn J. Nass on "Impact of sedation on the Performance Indicator of Colonic Intubation" Authors: Karlijn J. Nass, Sascha C. van Doorn, Manon van der Vlugt et al. Read more here: https://t.co/YiYMpAlfdA Watch the video here: https://t.co/M5c4NVzXUD

Jun 23, 2021 · 1 like · 11,534 followers View post →

All mentions

Endoscopy Journal
@endoscopyjrnl · X

Karlijn J. Nass on "Impact of sedation on the Performance Indicator of Colonic Intubation" Authors: Karlijn J. Nass, Sascha C. van Doorn, Manon van der Vlugt et al. Read more here: https://t.co/YiYMpAlfdA Watch the video here: https://t.co/M5c4NVzXUD

Jun 23, 2021 · 1 like · 11,534 followers View post →